Wound Induction Motor
Shenyang Electric Machine Manufacturing Co., Ltd. is one of the leading manufacturers and suppliers of wound induction motor in China. As we have world-leading production equipment and strong manufacturing capabilities, we warmly welcome you to buy premium wound induction motor at competitive price from our factory. Also, quotation is available.
The Wound Induction Motor, also named slip ring asynchronous motor, is a professional three-phase industrial motor manufactured strictly in accordance with IEC 60034 international standards. Different from conventional squirrel-cage motors, it adopts insulated three-phase symmetrical distributed rotor windings led out via slip rings and carbon brushes, allowing external connection of adjustable resistors or liquid rheostats for controllable operating performance.
Selection Guide
|
Parameter Item |
Parameter Details |
|
Product Series |
DGAM - WA PB / WW PB Subseries Motor |
|
Application Industries |
Mining / Construction Materials / Metallurgy / Non-Ferrous Metal Smelting |
|
Applicable Standards |
IEC |
|
Frame Diameter Range |
Φ990 - Φ2600 |
|
Power Range |
500 kW - 8000 kW |
|
Rated Voltage |
3 kV / 6 kV / 10 kV |
|
Applicable Frequency |
50 Hz / 60 Hz |
|
IP Rating |
IP00 / IP20 / IP21 / IP23 / IP44 |
|
Mounting Method |
IM7211 / IM7311 / IM7321 |
|
Cooling Method |
IC01 / IC97W |
|
Bearing Type |
Pedestal Sliding Bearing |
|
Insulation Class |
F / H |
|
Rotor Type |
Wound Rotor |
| Product Characteristic 1 / Product Characteristic 2 | ||||||||||
| Product Characteristic 1 | Designation Explanation | Product Characteristic 2 | Designation Explanation | |||||||
| HR | Rib-cooled | E4 | IE4 | |||||||
| BO | Box-type Open | E3 | IE3 | |||||||
| BA | Box-type Air-cooled | E2 | IE2 | |||||||
| BW | Box-type Water-cooled | VF | Variable Frequency | |||||||
| WO | Wound rotor Open | V | Vertical Mounting | |||||||
| WA | Wound rotor Air-cooled | PB | Pedestal Bearing | |||||||
| WW | Wound rotor Water-cooled | |||||||||
| SP | Special | |||||||||
| Cooling Method | ||||||||||
| Product Characteristic | No. | Cooling Method | Product Characteristic |
No. | Cooling Method | Product Characteristic |
No. | Cooling Method |
||
| HR | 1 | IC411 | WO | 1 | IC01 | SP | 411 | IC411 | ||
| 6 | IC416 | 6 | IC06 | 416 | IC416 | |||||
| BO | 1 | IC01 | WA | 1 | IC611 | 1 | IC01 | |||
| 6 | IC06 | 6 | IC616 | 6 | IC06 | |||||
| BA | 1 | IC611 | 66 | IC666 | 611 | IC611 | ||||
| 6 | IC616 | WW | 1 | IC81W | 616 | IC616 | ||||
| 66 | IC666 | 6 | IC86W | 666 | IC666 | |||||
| BW | 1 | IC81W | 81 | IC81W | ||||||
| 6 | IC86W | 86 | IC86W | |||||||
| 37 | IC37 | |||||||||
| Frame Size | ||||||||||
| LV(Low Voltage) ≤ 1000 V |
MV(Medium Voltage) 1120 V ~ 6600 V |
HV(High Voltage) 10000 V ~ 13800 V |
||||||||
| 80 | 315 | 355 | 355 | |||||||
| 90 | 355 | 400 | 400 | |||||||
| 100 | 400 | 450 | 450 | |||||||
| 112 | 450 | 500 | 500 | |||||||
| 132 | 500 | 560 | 560 | |||||||
| 160 | 560 | 630 | 630 | |||||||
| 180 | 630 | 710 | 710 | |||||||
| 200 | -- | 800 | 800 | |||||||
| 225 | -- | 900 | 900 | |||||||
| 250 | -- | 1000 | 1000 | |||||||
| 280 | -- | 1120 | 1120 | |||||||
| Speed Grade | ||||||||||
| Poles | Synchronous Speed | Poles | Synchronous Speed | Poles | Synchronous Speed | |||||
| 2 | 3000 rpm | 10 | 600 rpm | 18 | 333 rpm | |||||
| 4 | 1500 rpm | 12 | 500 rpm | 20 | 300 rpm | |||||
| 6 | 1000 rpm | 14 | 428.5 rpm | |||||||
| 8 | 750 rpm | 16 | 375 rpm | |||||||
Operation & Maintenance Notes
Standard operation and regular maintenance can effectively avoid failure, reduce wear and extend the service life of the wound induction motor.
Standard operation and regular maintenance can effectively avoid failure, reduce wear and extend the service life of the wound induction motor.
1. Pre-operation Check
Check the insulation resistance of stator and rotor windings before startup. Ensure the slip ring and carbon brush assembly are clean and in good contact. Verify external rotor resistance or rheostat devices are correctly connected to avoid abnormal starting current.
2. Startup & Running Precautions
Strictly avoid direct full-voltage startup without external resistance. Keep stable voltage and load during operation. Frequent overload and long-time locked-rotor operation are forbidden to prevent winding overheating and burnout.
3. Slip Ring & Carbon Brush Maintenance
Regularly check brush wear, spring pressure and sliding flexibility. Keep the slip ring surface smooth and clean without spark traces. Clean internal carbon dust periodically to prevent insulation deterioration and flashover.
4. Daily Running Monitoring
Monitor motor temperature, running current, vibration and noise in real time. Stop operation immediately if continuous sparking, overheating or abnormal vibration occurs, and troubleshoot in time.
FAQ
Q1: What is the biggest advantage of wound rotor industrial motors?
A1: They achieve low starting current and high starting torque, enabling smooth startup under heavy load and frequent impact load conditions, which is ideal for industrial heavy machinery.
Q2: Can this motor support speed regulation?
A2: Yes. By connecting external rotor resistance, it realizes stable and stepless speed adjustment, meeting variable-speed operation demands for production equipment.
Q4: What kind of industrial equipment is this motor suitable for?
A4: Professional and reliable, thewound induction motor is widely used for ball mills, crushers, conveyors and hoisters in mining, metallurgy and cement industries.
Hot Tags: wound induction motor, China wound induction motor manufacturers, suppliers, factory
Next