Variable Frequency High Voltage Asynchronous Motor

Variable Frequency High Voltage Asynchronous Motor

The variable frequency high voltage asynchronous motor uses H355-H1120 frames, 0-100 Hz running range, and inverter-duty cooling.
Send Inquiry
Product Introduction

Shenyang Electric Machine Manufacturing Co., Ltd. is one of the leading manufacturers and suppliers of variable frequency high voltage asynchronous motor in China. As we have world-leading production equipment and strong manufacturing capabilities, we warmly welcome you to buy premium variable frequency high voltage asynchronous motor at competitive price from our factory. Also, quotation is available.

 

Our variable frequency high voltage asynchronous motor is engineered for seamless integration with high-voltage inverter drives. It delivers precise speed control for fans, pumps, compressors, and mills to match dynamic process requirements. Featuring forced ventilation for optimal cooling during low-speed operation, this motor ensures steady running, high reliability, and maximum energy efficiency across its entire speed range.

 

Selection Guide

 

Parameter

Details

Product Series DGAM - BW Subseries Motor

Application Industries

Power plants / Metallurgy / Mining / Construction Materials / Air separation and compression / Water conservancy & water affairs / Energy and chemical industry / Non-Ferrous Metal Smelting

Applicable Standards

IEC

Frame Range

H355 - H1120

Power Range

185 kW - 20000 kW

Rated Voltage

380 V / 3 kV / 6 kV / 10 kV

Applicable Frequency

0-100 Hz

IP Rating

IP 54 / IP 55

Mounting Method

IM B3

Cooling Method

IC 616 / IC 666 / IC 81W / IC 86W

Bearing type

Rolling bearing / Sliding bearing

Insulation Class

F / H

Rotor Type

Squirrel Cage rotor

 

Product Characteristic 1 / Product Characteristic 2

Product Characteristic 1

Designation Explanation

Product Characteristic 2

Designation Explanation

HR

Rib-cooled

E4

IE4

BO

Box-type Open

E3

IE3

BA

Box-type Air-cooled

E2

IE2

BW

Box-type Water-cooled

VF

Variable Frequency

WO

Wound rotor Open

V

Vertical Mounting

WA

Wound rotor Air-cooled

PB

Pedestal Bearing

WW

Wound rotor Water-cooled

 

 

SP

Special

 

 

Cooling Method

Product Characteristic

No.

Cooling Method

Product
Characteristic

No.

Cooling Method

Product
Characteristic

No.

Cooling
Method

HR

1

IC411

WO

1

IC01

SP

411

IC411

6

IC416

 

6

IC06

 

416

IC416

BO

1

IC01

WA

1

IC611

 

1

IC01

6

IC06

 

6

IC616

 

6

IC06

BA

1

IC611

 

66

IC666

 

611

IC611

6

IC616

WW

1

IC81W

 

616

IC616

66

IC666

 

6

IC86W

 

666

IC666

BW

1

IC81W

 

 

 

 

81

IC81W

6

IC86W

 

 

 

 

86

IC86W

 

 

 

 

 

 

37

IC37

Frame Size

LV(Low Voltage‌)
≤ 1000 V

MV(Medium Voltage)
1120 V ~ 6600 V

HV(High Voltage)
10000 V ~ 13800 V

80

315

355

355

90

355

400

400

100

400

450

450

112

450

500

500

132

500

560

560

160

560

630

630

180

630

710

710

200

--

800

800

225

--

900

900

250

--

1000

1000

280

--

1120

1120

Speed Grade

Poles

Synchronous Speed

Poles

Synchronous Speed

Poles

Synchronous Speed

2

3000 rpm

10

600 rpm

18

333 rpm

4

1500 rpm

12

500 rpm

20

300 rpm

6

1000 rpm

14

428.5 rpm

 

 

8

750 rpm

16

375 rpm

 

 

 

Product Applications

 

Power Generation: Drives feedwater pumps, draft fans, and coal mills; key features include flexible speed regulation and significant energy savings.

Metallurgy: Used for blast furnace blowers, descaling pumps, and rolling mills; key features include resilience against frequent start-stop cycles and high impact resistance.

Mining: Drives ball mills, heavy-duty hoists, and drainage pumps; key features include high torque at low frequencies, enabling heavy-load operation and steep-incline hauling.

Building Materials: Used for vertical mills, rotary kilns, and large exhaust fans; key features include smooth, shock-free starting that reduces mechanical wear.

Water Utilities: Drives feedwater pumps, flood control pumps, and sewage pumps; key features include automatic variable-frequency control based on water pressure, completely eliminating water hammer.

Non-ferrous Smelting: Used for highly corrosive circulation pumps and process fans; key features include corrosion and wear resistance, as well as the ability to withstand harsh operating conditions.

 

Components

 

Component

Function

Stator

Contains the winding for inverter high-voltage use.

Rotor

Turns the load through the 0-100 Hz range.

Frame

Keeps the H355 to H1120 frame rigid.

Bearing system

Supports the shaft while speed changes.

Cooling section

Works with IC 616 / IC 666 / IC 81W / IC 86W

cooling.

 

Motor energy efficiency rating

 

A variable frequency high voltage asynchronous motor's energy efficiency rating is a key indicator of energy loss during the conversion of electrical energy into mechanical energy. Which corresponds to the international IEC 60034-30 IE (International Efficiency) classification system; ratings range IE4; with efficiency increasing and energy losses decreasing at each successive level.

 

FAQ

 

Q: What is the running range for variable frequency high voltage asynchronous motor?

A: The range is 0-100 Hz.

Q: What IP grade is used?

A: IP 54 / IP 55 is used.

Q: What should stay as supplied?

A: Keep the listed frame and output. Do not alter voltage, frequency, IP grade, cooling code, mounting, or bearing type.

 

Hot Tags: variable frequency high voltage asynchronous motor, China variable frequency high voltage asynchronous motor manufacturers, suppliers, factory