Variable Frequency High Voltage Asynchronous Motor
Shenyang Electric Machine Manufacturing Co., Ltd. is one of the leading manufacturers and suppliers of variable frequency high voltage asynchronous motor in China. As we have world-leading production equipment and strong manufacturing capabilities, we warmly welcome you to buy premium variable frequency high voltage asynchronous motor at competitive price from our factory. Also, quotation is available.
Our variable frequency high voltage asynchronous motor is engineered for seamless integration with high-voltage inverter drives. It delivers precise speed control for fans, pumps, compressors, and mills to match dynamic process requirements. Featuring forced ventilation for optimal cooling during low-speed operation, this motor ensures steady running, high reliability, and maximum energy efficiency across its entire speed range.
Selection Guide
|
Parameter |
Details |
| Product Series | DGAM - BW Subseries Motor |
|
Application Industries |
Power plants / Metallurgy / Mining / Construction Materials / Air separation and compression / Water conservancy & water affairs / Energy and chemical industry / Non-Ferrous Metal Smelting |
|
Applicable Standards |
IEC |
|
Frame Range |
H355 - H1120 |
|
Power Range |
185 kW - 20000 kW |
|
Rated Voltage |
380 V / 3 kV / 6 kV / 10 kV |
|
Applicable Frequency |
0-100 Hz |
|
IP Rating |
IP 54 / IP 55 |
|
Mounting Method |
IM B3 |
|
Cooling Method |
IC 616 / IC 666 / IC 81W / IC 86W |
|
Bearing type |
Rolling bearing / Sliding bearing |
|
Insulation Class |
F / H |
|
Rotor Type |
Squirrel Cage rotor |
|
Product Characteristic 1 / Product Characteristic 2 |
||||||||||
|
Product Characteristic 1 |
Designation Explanation |
Product Characteristic 2 |
Designation Explanation |
|||||||
|
HR |
Rib-cooled |
E4 |
IE4 |
|||||||
|
BO |
Box-type Open |
E3 |
IE3 |
|||||||
|
BA |
Box-type Air-cooled |
E2 |
IE2 |
|||||||
|
BW |
Box-type Water-cooled |
VF |
Variable Frequency |
|||||||
|
WO |
Wound rotor Open |
V |
Vertical Mounting |
|||||||
|
WA |
Wound rotor Air-cooled |
PB |
Pedestal Bearing |
|||||||
|
WW |
Wound rotor Water-cooled |
|
|
|||||||
|
SP |
Special |
|
|
|||||||
|
Cooling Method |
||||||||||
|
Product Characteristic |
No. |
Cooling Method |
Product |
No. |
Cooling Method |
Product |
No. |
Cooling |
||
|
HR |
1 |
IC411 |
WO |
1 |
IC01 |
SP |
411 |
IC411 |
||
|
6 |
IC416 |
|
6 |
IC06 |
|
416 |
IC416 |
|||
|
BO |
1 |
IC01 |
WA |
1 |
IC611 |
|
1 |
IC01 |
||
|
6 |
IC06 |
|
6 |
IC616 |
|
6 |
IC06 |
|||
|
BA |
1 |
IC611 |
|
66 |
IC666 |
|
611 |
IC611 |
||
|
6 |
IC616 |
WW |
1 |
IC81W |
|
616 |
IC616 |
|||
|
66 |
IC666 |
|
6 |
IC86W |
|
666 |
IC666 |
|||
|
BW |
1 |
IC81W |
|
|
|
|
81 |
IC81W |
||
|
6 |
IC86W |
|
|
|
|
86 |
IC86W |
|||
|
|
|
|
|
|
|
37 |
IC37 |
|||
|
Frame Size |
||||||||||
|
LV(Low Voltage) |
MV(Medium Voltage) |
HV(High Voltage) |
||||||||
|
80 |
315 |
355 |
355 |
|||||||
|
90 |
355 |
400 |
400 |
|||||||
|
100 |
400 |
450 |
450 |
|||||||
|
112 |
450 |
500 |
500 |
|||||||
|
132 |
500 |
560 |
560 |
|||||||
|
160 |
560 |
630 |
630 |
|||||||
|
180 |
630 |
710 |
710 |
|||||||
|
200 |
-- |
800 |
800 |
|||||||
|
225 |
-- |
900 |
900 |
|||||||
|
250 |
-- |
1000 |
1000 |
|||||||
|
280 |
-- |
1120 |
1120 |
|||||||
|
Speed Grade |
||||||||||
|
Poles |
Synchronous Speed |
Poles |
Synchronous Speed |
Poles |
Synchronous Speed |
|||||
|
2 |
3000 rpm |
10 |
600 rpm |
18 |
333 rpm |
|||||
|
4 |
1500 rpm |
12 |
500 rpm |
20 |
300 rpm |
|||||
|
6 |
1000 rpm |
14 |
428.5 rpm |
|
|
|||||
|
8 |
750 rpm |
16 |
375 rpm |
|
|
|||||
Product Applications
Power Generation: Drives feedwater pumps, draft fans, and coal mills; key features include flexible speed regulation and significant energy savings.
Metallurgy: Used for blast furnace blowers, descaling pumps, and rolling mills; key features include resilience against frequent start-stop cycles and high impact resistance.
Mining: Drives ball mills, heavy-duty hoists, and drainage pumps; key features include high torque at low frequencies, enabling heavy-load operation and steep-incline hauling.
Building Materials: Used for vertical mills, rotary kilns, and large exhaust fans; key features include smooth, shock-free starting that reduces mechanical wear.
Water Utilities: Drives feedwater pumps, flood control pumps, and sewage pumps; key features include automatic variable-frequency control based on water pressure, completely eliminating water hammer.
Non-ferrous Smelting: Used for highly corrosive circulation pumps and process fans; key features include corrosion and wear resistance, as well as the ability to withstand harsh operating conditions.
Components
|
Component |
Function |
|
Stator |
Contains the winding for inverter high-voltage use. |
|
Rotor |
Turns the load through the 0-100 Hz range. |
|
Frame |
Keeps the H355 to H1120 frame rigid. |
|
Bearing system |
Supports the shaft while speed changes. |
|
Cooling section |
Works with IC 616 / IC 666 / IC 81W / IC 86W cooling. |
Motor energy efficiency rating
A variable frequency high voltage asynchronous motor's energy efficiency rating is a key indicator of energy loss during the conversion of electrical energy into mechanical energy. Which corresponds to the international IEC 60034-30 IE (International Efficiency) classification system; ratings range IE4; with efficiency increasing and energy losses decreasing at each successive level.
FAQ
Q: What is the running range for variable frequency high voltage asynchronous motor?
A: The range is 0-100 Hz.
Q: What IP grade is used?
A: IP 54 / IP 55 is used.
Q: What should stay as supplied?
A: Keep the listed frame and output. Do not alter voltage, frequency, IP grade, cooling code, mounting, or bearing type.
Hot Tags: variable frequency high voltage asynchronous motor, China variable frequency high voltage asynchronous motor manufacturers, suppliers, factory
Previous
No InformationNext
No InformationYou Might Also Like